{"id":4363,"date":"2015-06-29T08:21:17","date_gmt":"2015-06-29T06:21:17","guid":{"rendered":"https:\/\/www.utp-umwelttechnik-poehnl.de\/fully-biological-wastewater-treatment-plants\/"},"modified":"2026-09-30T11:40:28","modified_gmt":"2026-09-30T09:40:28","slug":"wastewater-treatment-plants","status":"publish","type":"page","link":"https:\/\/dev.utp-umwelttechnik-poehnl.de\/en\/wastewater-treatment-plants\/","title":{"rendered":"Wastewater treatment plants"},"content":{"rendered":"\n<div class=\"et_pb_section_0 et_pb_section et_section_regular et_block_section\"><div class=\"et_pb_row_0 et_pb_row et_block_row\"><div class=\"et_pb_column_0 et_pb_column et_pb_column_1_2 et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_image_0 et_pb_image et_pb_module et_block_module\"><span class=\"et_pb_image_wrap\"><img decoding=\"async\" src=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/IMG_9630-e1594058593104.jpg\" width=\"1500\" height=\"843\" srcset=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/IMG_9630-e1594058593104.jpg 1500w, https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/IMG_9630-e1594058593104-1280x720.jpg 1280w, https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/IMG_9630-e1594058593104-980x551.jpg 980w, https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/IMG_9630-e1594058593104-480x270.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 1500px, 100vw\" class=\"wp-image-202\" title=\"Cleaning systems from 50 PE\" \/><\/span><\/div><\/div><div class=\"et_pb_column_1 et_pb_column et_pb_column_1_2 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_text_0 et_pb_text et_pb_bg_layout_dark et_animated et_pb_module et_block_module\"><div class=\"et_pb_text_inner\"><h1>Municipal and industrial wastewater treatment plants<\/h1>\n<p>Whether new construction, upgrading or rehabilitation, we are your contact for individual wastewater solutions for wastewater treatment plants. From planning to eady-to-use-delivery and installation, you get everything from a single source.<\/p>\n<\/div><\/div><\/div><\/div><\/div><div class=\"et_pb_section_1 et_pb_section et_section_regular et_block_section\"><div class=\"et_pb_row_1 et_pb_row et_block_row\"><div class=\"et_pb_column_2 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_text_1 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module et_pb_text_align_center\"><div class=\"et_pb_text_inner\"><h2><span style=\"color: #ffffff; font-size: 30px;\">Cleaning systems from 50 PE<\/span><\/h2>\n<p><span style=\"color: #ffffff;\">With our kl\u00e4ropro and kl\u00e4rocom cleaning systems, we have the right solution for every type of wastewater.<\/span><\/p>\n<\/div><\/div><\/div><\/div><\/div><div class=\"et_pb_section_2 et_pb_section et_section_regular et_block_section\"><div class=\"et_pb_row_2 et_pb_row et_pb_equal_columns et_block_row\"><div class=\"et_pb_column_3 et_pb_column et_pb_column_1_2 et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_team_member_0 et_pb_team_member et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_team_member_image et-waypoint et_pb_animation_off\"><img decoding=\"async\" src=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/UTP-Umwelttechnik_klaeropro-e1495445126238.png\" width=\"309\" height=\"204\" srcset=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/UTP-Umwelttechnik_klaeropro-e1495445126238.png 309w\" sizes=\"(max-width: 309px) 100vw, 309px\" class=\"wp-image-351\" \/><\/div><div class=\"et_pb_team_member_description\"><div class=\"et_pb_team_member_description_content\"><h3>kl\u00e4ropro\u00ae - The industrial wastewater treatment plant<\/h3>\n<p style=\"text-align: justify;\">kl\u00e4ropro wastewater treatment plants are special plants for object-related application, in which cases no standardized wastewater treatment plants can be realized. Especially for objects with very special wastewaters or strongly fluctuation inflow amounts, kl\u00e4ropro wastewater treatment plants are the right choice. This type of wastewater treatment plant is based on our standardized modular system; however, the single modules will be adapted to the respective application individually. <\/p>\n<\/div><\/div><\/div><div class=\"et_pb_cta_0 et_pb_promo et_pb_bg_layout_dark et_clickable et_pb_module et_block_module\"><div class=\"et_pb_promo_description\"><h4 class=\"et_pb_module_header\">More information on the industrial wastewater treatment plant<\/h4><\/div><div class=\"et_pb_button_wrapper\"><a class=\"et_pb_button et_pb_promo_button\" href=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/en\/wastewater-treatment-plants\/klaeropro\/\">Continue to kl\u00e4ropro<\/a><\/div><\/div><\/div><div class=\"et_pb_column_4 et_pb_column et_pb_column_1_2 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_team_member_1 et_pb_team_member et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_team_member_image et-waypoint et_pb_animation_off\"><img decoding=\"async\" src=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/KLAEROCOM_collect-frei.png\" width=\"309\" height=\"206\" srcset=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/KLAEROCOM_collect-frei.png 309w, https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/KLAEROCOM_collect-frei-300x200.png 300w\" sizes=\"(max-width: 309px) 100vw, 309px\" class=\"wp-image-465\" \/><\/div><div class=\"et_pb_team_member_description\"><div class=\"et_pb_team_member_description_content\"><h3>kl\u00e4rocom - the municipal wastewater treatment plant<\/h3>\n<p style=\"text-align: justify;\">kl\u00e4rocom wastewater treatment plants are standard plants modularly built in a modular system that has been developed especially for the cleaning of municipal wastewaters. Due to the combination of individual SBR modules, nearly all technically possible cleaning parameters can be realized from 51 to 300 PE. Our kl\u00e4rocom wastewater treatment plants have been used successfully for years at small communities. Based on our constantly developed further SBR technology, the utp engineers and technicians team always finds the right solution for you.   <\/p>\n<\/div><\/div><\/div><div class=\"et_pb_cta_1 et_pb_promo et_pb_bg_layout_dark et_clickable et_pb_module et_block_module\"><div class=\"et_pb_promo_description\"><h4 class=\"et_pb_module_header\">Further information on the municipal wastewater treatment plant<\/h4><\/div><div class=\"et_pb_button_wrapper\"><a class=\"et_pb_button et_pb_promo_button\" href=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/en\/wastewater-treatment-plants\/klaerocom\/\">Continue to kl\u00e4rocom<\/a><\/div><\/div><\/div><\/div><\/div><div class=\"et_pb_section_3 et_pb_section et_section_regular et_block_section\"><div class=\"et_pb_row_3 et_pb_row et_block_row\"><div class=\"et_pb_column_5 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_text_2 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module\"><div class=\"et_pb_text_inner\"><h2 style=\"text-align: center;\">Wastewater treatment plants from utp?<\/h2>\n<h3 style=\"text-align: center;\">A good choice thanks to durability and low operating costs<\/h3>\n<\/div><\/div><\/div><\/div><div class=\"et_pb_row_4 et_pb_row et_block_row\"><div class=\"et_pb_column_6 et_pb_column et_pb_column_1_3 et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_blurb_0 et_pb_blurb et_pb_bg_layout_light et_pb_text_align_center et_pb_blurb_position_top et_pb_module et_block_module\"><div class=\"et_pb_blurb_content\"><div class=\"et_pb_main_blurb_image et_animated\"><span class=\"et_pb_image_wrap et_pb_only_image_mode_wrap\"><img decoding=\"async\" src=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Elektrik-Symbol-utp-farbe-e1495462038305.png\" width=\"149\" height=\"150\" srcset=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Elektrik-Symbol-utp-farbe-e1495462038305.png 149w\" sizes=\"(max-width: 149px) 100vw, 149px\" class=\"wp-image-253\" \/><\/span><\/div><div class=\"et_pb_blurb_container\"><h4 class=\"et_pb_module_header\">No electrics in the waste water<\/h4><div class=\"et_pb_blurb_description\"><p>We think that power and water do not get along with each other so well. That is why we installed all live parts outside the tank in the control cabinet.<\/p>\n<\/div><\/div><\/div><\/div><\/div><div class=\"et_pb_column_7 et_pb_column et_pb_column_1_3 et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_blurb_1 et_pb_blurb et_pb_bg_layout_light et_pb_text_align_center et_pb_blurb_position_top et_pb_module et_block_module\"><div class=\"et_pb_blurb_content\"><div class=\"et_pb_main_blurb_image et_animated\"><span class=\"et_pb_image_wrap et_pb_only_image_mode_wrap\"><img decoding=\"async\" src=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Mechanik-symbol-utp-farbe-e1495461998603.png\" width=\"149\" height=\"150\" srcset=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Mechanik-symbol-utp-farbe-e1495461998603.png 149w\" sizes=\"(max-width: 149px) 100vw, 149px\" class=\"wp-image-254\" \/><\/span><\/div><div class=\"et_pb_blurb_container\"><h4 class=\"et_pb_module_header\">No mechanics in the waste water<\/h4><div class=\"et_pb_blurb_description\"><p>We do not have a lot of mechanics, however, the mechanics we have is very robust. That is why we use with all our small wastewater treatment plants only linear piston compressors with five years of warranty. Out of conviction. It could not be any better!<\/p>\n<\/div><\/div><\/div><\/div><\/div><div class=\"et_pb_column_8 et_pb_column et_pb_column_1_3 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_blurb_2 et_pb_blurb et_pb_bg_layout_light et_pb_text_align_center et_pb_blurb_position_top et_pb_module et_block_module\"><div class=\"et_pb_blurb_content\"><div class=\"et_pb_main_blurb_image et_animated\"><span class=\"et_pb_image_wrap et_pb_only_image_mode_wrap\"><img decoding=\"async\" src=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Symbol-Pumpe-utp-farbe-e1495461952654.png\" width=\"150\" height=\"150\" srcset=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Symbol-Pumpe-utp-farbe-e1495461952654.png 150w\" sizes=\"(max-width: 150px) 100vw, 150px\" class=\"wp-image-255\" \/><\/span><\/div><div class=\"et_pb_blurb_container\"><h4 class=\"et_pb_module_header\">No electric pumps in the waste water<\/h4><div class=\"et_pb_blurb_description\"><p>We swear in wear-free, compressed air driven lifter without electric pumps. What is supposed to break? Our compressed air driven lifters survive definitely every electrical pump!<\/p>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"et_pb_section_4 et_pb_section et_section_regular et_block_section\" id=\"#technologie\"><div class=\"et_pb_row_5 et_pb_row et_block_row\"><div class=\"et_pb_column_9 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_text_3 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module et_pb_text_align_center\"><div class=\"et_pb_text_inner\"><h2>How does a fully biological wastewater treatment plant work?<\/h2>\n<p>The <b>functionality<\/b> of our kl\u00e4ropro wastewater treatment plants is <b>based on the<\/b> <b>SBR process<\/b>.<br \/> <span>The mechanical preliminary cleaning takes place in phase one, the biological cleaning as well as the secondary cleaning take place combined in one chamber.<\/span><\/p>\n<\/div><\/div><\/div><\/div><div class=\"et_pb_row_6 et_pb_row et_block_row\"><div class=\"et_pb_column_10 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_accordion_0 et_pb_accordion et_pb_module et_block_module\"><div class=\"et_pb_accordion_item_0 et_pb_accordion_item et_pb_toggle et_pb_module et_pb_toggle_open et_block_module\"><h4 class=\"et_pb_toggle_title\">1. Inlet<\/h4><div class=\"et_pb_toggle_content\"><p><a href=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Zulauf.png\"><img decoding=\"async\" width=\"300\" height=\"200\" class=\"wp-image-458 alignnone size-medium\" alt=\"\" src=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Zulauf-300x200.png\" srcset=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Zulauf-300x200.png 300w, https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Zulauf-768x512.png 768w, https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Zulauf-1024x683.png 1024w, https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Zulauf-1080x720.png 1080w, https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Zulauf.png 1500w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>The wastewaters reach by means of an inlet sewer the preliminary stage of the wastewater treatment plant. Floating material as well as settleable solids are kept back. As the treatment plant is operating with impoundment, the incoming wastewater is initially buffered in the preliminary tank.   <\/p>\n<\/div><\/div><div class=\"et_pb_accordion_item_1 et_pb_accordion_item et_pb_toggle et_pb_module et_pb_toggle_close et_block_module\"><h4 class=\"et_pb_toggle_title\">2. Filling<\/h4><div class=\"et_pb_toggle_content\"><p class=\"et-fb-mce-line-break-holder\"><a href=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Bef%C3%BCllen.png\"><img decoding=\"async\" width=\"300\" height=\"200\" class=\"wp-image-454 alignnone size-medium\" alt=\"\" src=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Bef%C3%BCllen-300x200.png\"><\/a><\/p>\n<p>From the priliminary tank\/buffer, the pre-cleaned wastewater reaches by means of an airlift pump system the reactor (sequencing batch reactor). If the wastewater treatment plant has more than one reactor, each reactor is alternately loaded. In order to reach an energetic optimization of the wastewater treatment plant and, depending on the amount of wastewater, there are different operating cycles. This way, we can compensate possible fluctuations of the amount of the wastewater. The controlling of the cycles takes place automatically as well as needs oriented depending on the inflowing amount of wastewater or rather on the change of the filling level in the preliminary\/buffer tank.    <\/p>\n<\/div><\/div><div class=\"et_pb_accordion_item_2 et_pb_accordion_item et_pb_toggle et_pb_module et_pb_toggle_close et_block_module\"><h4 class=\"et_pb_toggle_title\">3. Mixing and reaction phase<\/h4><div class=\"et_pb_toggle_content\"><p class=\"et-fb-mce-line-break-holder\"><a href=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Bel%C3%BCften.png\"><img decoding=\"async\" width=\"300\" height=\"200\" class=\"wp-image-455 alignnone size-medium\" alt=\"\" src=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Bel%C3%BCften-300x200.png\"><\/a><\/p>\n<p>In order to circulate and aerate the whole content of the reactor, diaphragm disks, which are installed on the floor of the reactor, blow air into the wastewater periodically. A compressor, set up in a dry place, generates the necessary amount of air in order to aerate the wastewater with fine bubbles highly efficiently. The rising air bubbles generate a water cylinder that mixes the activated sludge and the wastewater thoroughly. That way we reach a high level of cleaning performance.    <\/p>\n<\/div><\/div><div class=\"et_pb_accordion_item_3 et_pb_accordion_item et_pb_toggle et_pb_module et_pb_toggle_close et_block_module\"><h4 class=\"et_pb_toggle_title\">4. Sedimentation phase<\/h4><div class=\"et_pb_toggle_content\"><p class=\"et-fb-mce-line-break-holder\"><a href=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Absetzen.png\"><img decoding=\"async\" width=\"300\" height=\"200\" class=\"wp-image-453 alignnone size-medium\" alt=\"\" src=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Absetzen-300x200.png\" srcset=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Absetzen-300x200.png 300w, https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Absetzen-768x512.png 768w, https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Absetzen-1024x683.png 1024w, https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Absetzen-1080x720.png 1080w, https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Absetzen.png 1500w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>During a one-hour-resting-period, the wastewater will not be aerated further. As a result, the content of the reactor is divided horizontally in a sludge and a clearwater zone. The generated activated sludge settles on the ground of the tank.  <\/p>\n<\/div><\/div><div class=\"et_pb_accordion_item_4 et_pb_accordion_item et_pb_toggle et_pb_module et_pb_toggle_close et_block_module\"><h4 class=\"et_pb_toggle_title\">5. Excess sludge removal<\/h4><div class=\"et_pb_toggle_content\"><p><a href=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Sekund%C3%A4rschlammr%C3%BCckf%C3%BChrung.png\"><img decoding=\"async\" width=\"300\" height=\"200\" class=\"wp-image-457 alignnone size-medium\" alt=\"\" src=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Sekund%C3%A4rschlammr%C3%BCckf%C3%BChrung-300x200.png\"><\/a><\/p>\n<p>Before the last phase, the excess sludge, created during the cleaning process, will be removed. The duration of the phase depends on the height and is pre-set. An airlift pump transports the generated excess sludge for storage back to the buffer. The extraction area is given constructively by means of extraction hole.   <\/p>\n<\/div><\/div><div class=\"et_pb_accordion_item_5 et_pb_accordion_item et_pb_toggle et_pb_module et_pb_toggle_close et_block_module\"><h4 class=\"et_pb_toggle_title\">6. Clearwater extraction phase<\/h4><div class=\"et_pb_toggle_content\"><p><a href=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Klarwasserabzug.png\"><img decoding=\"async\" width=\"300\" height=\"200\" class=\"wp-image-456 alignnone size-medium\" alt=\"\" src=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Klarwasserabzug-300x200.png\" srcset=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Klarwasserabzug-300x200.png 300w, https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Klarwasserabzug-768x512.png 768w, https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Klarwasserabzug-1024x683.png 1024w, https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Klarwasserabzug-1080x720.png 1080w, https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/2017\/05\/Klarwasserabzug.png 1500w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>As a last step, an airlift pump carries the cleaned wastewater into the outlet of the wastewater treatment plant. The water is conducted by means of an outlet channel to a receiving water\/seepage etc. With that, the cleaning cycle is finished; a new one starts as soon as there is enough wastewater in the treatment plant.  <\/p>\n<\/div><\/div><\/div><\/div><\/div><\/div><div class=\"et_pb_section_5 et_pb_section et_section_regular et_block_section\"><div class=\"et_pb_row_7 et_pb_row et_block_row\"><div class=\"et_pb_column_11 et_pb_column et_pb_column_1_2 et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_text_4 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module\"><div class=\"et_pb_text_inner\"><h2 class=\"h2-as-h3 hyphens-none\">The advantages of a fully biological wastewater treatment plant<\/h2>\n<ul>\n<li>excellent cleaning performance<\/li>\n<li>cheap purchase<\/li>\n<li>only 2 tanks necessary<\/li>\n<li>small tank volume necessary<\/li>\n<li>Retrofitting possible<\/li>\n<li>less maintenance-intensive<\/li>\n<\/ul>\n<\/div><\/div><\/div><div class=\"et_pb_column_12 et_pb_column et_pb_column_1_2 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_video_0 et_pb_video et_pb_module et_block_module\"><div class=\"et_pb_video_box\"> <div class=\"brlbs-cmpnt-container brlbs-cmpnt-content-blocker brlbs-cmpnt-with-individual-styles\" data-borlabs-cookie-content-blocker-id=\"youtube-content-blocker\" data-borlabs-cookie-content=\"PGlmcmFtZSB0aXRsZT0iQW5pbWF0aW9uc2ZpbG0gU0JSLVRlY2hub2xvZ2llIGVpbmVyIGtsw6Ryb2ZpeMKuIEtsZWlua2zDpHJhbmxhZ2UiIHdpZHRoPSIxMDgwIiBoZWlnaHQ9IjYwOCIgc3JjPSJodHRwczovL3d3dy55b3V0dWJlLW5vY29va2llLmNvbS9lbWJlZC9weUtKSXZtVERIWT9mZWF0dXJlPW9lbWJlZCIgIGFsbG93PSJhY2NlbGVyb21ldGVyOyBhdXRvcGxheTsgY2xpcGJvYXJkLXdyaXRlOyBlbmNyeXB0ZWQtbWVkaWE7IGd5cm9zY29wZTsgcGljdHVyZS1pbi1waWN0dXJlOyB3ZWItc2hhcmUiIHJlZmVycmVycG9saWN5PSJzdHJpY3Qtb3JpZ2luLXdoZW4tY3Jvc3Mtb3JpZ2luIiBhbGxvd2Z1bGxzY3JlZW4+PC9pZnJhbWU+\"><div class=\"brlbs-cmpnt-cb-preset-c brlbs-cmpnt-cb-youtube\"> <div class=\"brlbs-cmpnt-cb-thumbnail\" style=\"background-image: url('https:\/\/dev.utp-umwelttechnik-poehnl.de\/wp-content\/uploads\/borlabs-cookie\/1\/yt_pyKJIvmTDHY_hqdefault.jpg')\"><\/div> <div class=\"brlbs-cmpnt-cb-main\"> <div class=\"brlbs-cmpnt-cb-play-button\"><\/div> <div class=\"brlbs-cmpnt-cb-content\"> <p class=\"brlbs-cmpnt-cb-description\">You are currently viewing a placeholder content from <strong>YouTube<\/strong>. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.<\/p> <a class=\"brlbs-cmpnt-cb-provider-toggle\" href=\"#\" data-borlabs-cookie-show-provider-information role=\"button\">More Information<\/a> <\/div> <div class=\"brlbs-cmpnt-cb-buttons\"> <a class=\"brlbs-cmpnt-cb-btn\" href=\"#\" data-borlabs-cookie-unblock role=\"button\">Unblock content<\/a> <a class=\"brlbs-cmpnt-cb-btn\" href=\"#\" data-borlabs-cookie-accept-service role=\"button\" style=\"display: inherit\">Accept required service and unblock content<\/a> <\/div> <\/div> <\/div><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"et_pb_section_6 et_pb_section et_section_regular et_block_section\"><div class=\"et_pb_row_8 et_pb_row et_block_row\"><div class=\"et_pb_column_13 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_cta_2 et_pb_promo et_pb_bg_layout_dark et_pb_module et_block_module\"><div class=\"et_pb_promo_description\"><h3 class=\"et_pb_module_header\">Do you have any questions?<\/h3><div class=\"et_pb_promo_content\"><p>If you have any questions or would like us to prepare an individual offer for you, please contact us.<\/p>\n<\/div><\/div><div class=\"et_pb_button_wrapper\"><a class=\"et_pb_button et_pb_promo_button\" href=\"https:\/\/dev.utp-umwelttechnik-poehnl.de\/en\/contact\/\">Contact us<\/a><\/div><\/div><\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-4363","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/dev.utp-umwelttechnik-poehnl.de\/en\/wp-json\/wp\/v2\/pages\/4363","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dev.utp-umwelttechnik-poehnl.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/dev.utp-umwelttechnik-poehnl.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/dev.utp-umwelttechnik-poehnl.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dev.utp-umwelttechnik-poehnl.de\/en\/wp-json\/wp\/v2\/comments?post=4363"}],"version-history":[{"count":0,"href":"https:\/\/dev.utp-umwelttechnik-poehnl.de\/en\/wp-json\/wp\/v2\/pages\/4363\/revisions"}],"wp:attachment":[{"href":"https:\/\/dev.utp-umwelttechnik-poehnl.de\/en\/wp-json\/wp\/v2\/media?parent=4363"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}